Transmitter for Specific Conductivity, ACM-1
COMPACT-LINE measuring range: 0 up to 200 mS/cm With panel mounted housing or field mounted housing Input: 1x conductivity/resistance/TDS, 2 binary inputs 1x temperature/resistance/standard signal graphic display w. backlight max. 3 values, trend, bargraph Output: 2 relays (SPDT) 1 supply voltage f. sensors 17 VDC freely programmable, math and logic module Option: plug-in boards analogue output, power supply snesors, RS485, datalogger, Profibus, relays)
|
|
Transmitter for Specific Conductivity, ACM-X
EXPERT-LINE Measuring range: conductivity: 0 ... 2000 mS/cm resistance: 0 ... 86 M Ohm cm With panel mounted housing or field mounted housing Large LC-Display for text Alarm relays Two additional relays for use as control contacts Two digital inputs
|
|
Conductive Conductivity Measuring Cells, ACS-X
EXPERT-LINE Measuring range 1, K=0,01: 0,04 ... 20 µS/cm Measuring range 2, K=0,1: 0,1 ... 200 µS/cm Measuring range 3, K=1,0: 50 ... 500 µS/cm Measuring range 4, K= 1,0: 10 µS/cm ... 20 mS/cm Connection: NPT ½ or G1 Electrode Material: st. st. 1.4571 or. graphite Temperature sensor: Pt 100 possible
|
|
Inductive Conductivity Measuring Cell ACS-X0I
EXPERT-LINE Measuring range: 5 µS/cm up to 2000 mS/cm Connection: G3/4 of 1.4571 or 1 NPT of PEEK Material of sensor: PEEK (resistant to chemical attack) temperature range: -20 up to +130°C Pressure rating: up to 16 bar Cable: 5 meters fixed cable Temperature sensor: coated Pt 100 integrated
|
|
Conductive Conductivity Measuring Cells, ACS-Z
COMPACT-LINE Measuring range 1, K=0,01: 0,05 ... 10 µS/cm Measuring range 2, K=0,1: 1 ... 1000 µS/cm Measuring range 3, K=1,0: 10 µS/cm ... 15 mS/cm Connection: thread G ¾ A Electrode Material: st. st. 1.4571 bzw. graphite temperature range: up to 135°C (at 1 bar) Pressure rating: up to 16 bar (at 25°C) Temperature sensor: Pt 100 integrated
|
|
Inductive Conductivity / Concentration and Temperature Transmitter LCI
Measuring range: 0-500 µS/cm...0-2000 mS/cm Connection: G 1 ¼ AG - 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent® Material: PEEK. PVDF Max.pressure: 10 bar Max. temperature: 120 °C (short term 140 °C) Accuracy: 1 %
|
|
Hand-Held Conductivity Measuring Unit HND-C
Measuring range: conductivity: 0,0...200.0 mikroS up to 0,0...200.0 mS temperature: -5,0...+100,0 °C Accuracy: conductivity: ± 0,5v. MV, /± 0,3 % v. FS temperature: ± 0,2 % v. MV ± 0,3 K Supply: 9 V battery Hold function, min/max. -memory Output: RS 232 or USB
|
|
Accessories for Analysing Devices AZA, AZT, AZM
Immersion assemblies Flow assemblies Process assemblies Buffer solutions for pH and ORP Calibration solutions for conductivity temperature sensors Wall mounting set for field housing Pipe mounting set for field housing
|