Magnetic Level Switches M
For liquids Contact: max. 4 reed switches Connection:G 1/8...G 2 male, flange: DN50..DN125, 11/2....-4 Material: brass, st. st., PVC-U, PP, PVDF, NBR Max. pressure: 100 bar Max.temperature:150°C Liquid density: from 0,5 g/ml on
|
Magnetic Level Switches for Side Installations NS
For liquids Contact: max. 4 reed switches Connection:G 3/8...G 2 male, flange: DN50..DN125 Material:brass, st. st., PVC-U, PP Max. pressure: 100 bar Max.temperature:150°C Liquid density: ab 0,6 g/ml
|
Bypass Level Switch NBA, NBE
For liquids Contact: 1 reed switches Connection:G 3/8, R ½ Material:aluminum, st. st. Max. pressure: 10 bar Max.temperature: 90 °C Liquid density: from 0,65 g/ml on
|
Plastic Level Switch NKP
For liquids Contact: 1 reed switch Connection:G 1/2A female, ½ NPT, M16 Material:Polypropylen, PVDF Max. pressure: 10 bar Max.temperature:100°C Liquid density: from 0,6 g/ml on
|
Level Switch RFS
For liquids Contact: 1 reed switch Connection: ½ NPT Material: st. st. 1.4305 Max. pressure: 5 bar Max.temperature:120°C /ATEX: 60°C) Liquid density: from 0,7 g/ml Option: ATEX
|
Level Switch NV
For liquids Contact: 1 reed switch Connection:G ¾ male, ¾ NPT, M27x1,5 Material:brass, st. st. Max. pressure: 16 bar Max.temperature:110°C Liquid density: from 0,7 g/ml on
|
Float Level Switch NSP-S
For liquids Contact: 1 micro switch Connection: cable gland G1, G2 Material:Polypropylen Max. pressure:1 bar Max.temperature:85°C
|
Float Level Switch NSP-K
For liquids Contact: 1 micro switch Connection: cable gland G1, G2 Material:Polypropylen Max. pressure:2 bar Max.temperature:85°C
|
Float Level Switch NAB
For liquids Contact: 1 micro switch Material:Polypropylen, PP Max. pressure:5 bar Max.temperature:85°C
|
Float Level Switch NSM
For liquids Contact: 1 micro switch Material:Polypropylen PP, polyamide PA Max. pressure:3 bar Max.temperature:95°C
|
Float Level Switch NEC
For liquids Contact: 1 micro switch Material:Polypropylen, PP hypalon coated Max. pressure: 5,5 bar Max.temperature: 85°C
|
Float Level Switch NST
For liquids Contact: 1 reed contact Connection: cable gland G2 Material: PTFE Max. pressure:1 bar Max.temperature:150°C
|
Float Level Switch NSE
For liquids Contact: 1 reed contact Material: PTFE Max. pressure:15 bar Max.temperature:150°C
|
Dual Magnet Float Level Switch NGS
For liquids Contact: 1 micro switch Connection:square flange, G 2, 2 NPT DIN-flange: DN80, DN100 Material: st. st. 1.4571 Max. pressure: 25 bar Max.temperature:250°C Liquid density: ab 0,7 g/ml Certificates: ATEX, Germanischer Lloyd
|
Conductive Level Switch NES
For conductive liquids Contacts: 5 contacts via relays Connection:G 1/2, G 11/2 male, ½ NPT, 11/2 NPT male Material: st. st., hastelloy, titanium Max. pressure:30 bar Max.temperature:150°C For conductive liquids (>20 mikroS/cm)
|
Conductive Suspended Electrode NEH
For conductive liquids Contact: 5 contacts via relays Connection:G 1/2, G 11/2 male ½ NPT, 11/2 NPT male Material: st. st., hastelloy, titanium Max. pressure: 6 bar Max.temperature:150°C For conductive liquids (>20 mikroS/cm)
|
Conductive Level Switch (WHG) NEW
For conductive liquids Contact: 2 contacts via relays Connection:G 1, G 11/2 male, 1 NPT, 11/2 NPT male Material: st. st., hastelloy, titanium Max. pressure: pressureless Max.temperature:60°C For conductive liquids (>20 mikroS/cm)
|
Conductive Level Switch NEK
For conductive liquids Contact: 1 open collector or 1 relay Connection:G ¾ male, ¾ NPT Material: PPS, Polypropylen Max. pressure: 20 bar Max.temperature:85°C For conductive liquids (>28 mikroS/cm)
|
Conductive Level Switch LNK
For conductive liquids (>10 mikroS) Electrodes: 1-4 pcs, length: 4-2000 mm Connection: G 1/2, G 1 hygenic mounting system (EHEDG) hygenic DIN 11851, Tri-Clamp, weld on sleeve Material: st.st. 1.4404, Option: C-CTFE coating Max. pressure: 10 bar Max.Temperatur:100°C (CIP 150 °C) Options: head mounted transmitter f. 1 contact
|
Conductive Level Switch Compact LNK-K
for conductive liquids (>10 mikroS) Electrodes: 4 up to 2000 mm Connection: G ½ hygenic mounting system (EHEDG) hygenic DIN 11851, Tri-Clamp, weld on sleeve Material: st.st. 1.4404, option: E-CTFE coating Max. pressure: 10 bar Max.temperature:150°C Option: head mounted transmitter f. 1 contact
|
Rele z elektrodami za prevodna stikala NE-104, -304
za prevodna nivojska stikala NES, NEW, NEH izhod: 1 ali 2 nivojska stikala min/maks. nadzorniki napajanje: 24, 110, 230 VAC namestitev: standardno nosilo
|
Rele z elektrodami §19 WHG NE-204
za prevodna nivojska stikala NES, NEW, NEH izhod: 1 ali 2 nivojska stikala min/maks. nadzorniki napajanje: 24, 230 VAC namestitev: standardno nosilo Certifikat za tekočine, ki onesnažujejo vodo
|
Nivojski modul za prevodne nivojske sonde LNR
za prevodna nivojska stikala izhod: 1 PNP napajanje:15...36 VDC
|
Mikrovalno nivojsko stikalo LNM
Primerno tudi za neprevodne medije, občutljive na peno, ni za lepljive medije Priključki: G 1/2, M12x1,5; sanitarni sistem montaže (EHEDG) sanitarni DIN 11851, Tri-Clamp, var na rokavu Material: nerjaveče jeklo 1.4404 / PEEK Maks. tlak: 10 bar Maks. temperatura: 100 °C (CIP 150°C) Kontakt: odprt kolektor, PNP, 50 mA
|
Capacitive Level Limit Switch LNZ
As well for non conductive liquids sensitive to foam, not for adhesions Connection: G 1/2 hygenic mounting system (EHEDG) hygenic DIN 11851, Tri-Clamp, weld on sleeve Material: st.st. 1.4404 / PEEK Max. pressure: 10 bar Max. temperature: 100 °C (CIP 150°C) Contact: Open Collector, PNP, 200 mA
|
Capacitive Level Limit Switch NCW
For liquids Electrodes: max. 4 m Contact: 1 relay (max. 250 Vac, 1A) Connection: G 1 male, st. steel or G 2 male, PVDF Material Electrodes: st. steel with PTFE or PVDF coating Max. pressure: PN 10 bar Max. temperature: 90 °C (125 °C) Power supply: 24, 110, 230 VAC, 18..36 VDC
|
Capacitive Level Limit Switch NCW-H
For liquids Electrodes: max. 4 m Contact: 1 relay (max. 250 Vac, 1A) Connection: G 1 male, st. steel or G 2 male, PVDF Material Electrodes: st. steel with PTFE or PVDF coating Max. pressure: PN 10 bar Max. temperature: 125 °C Power supply: 24, 110, 230 VAC, 18..36 VDC
|
Ultrasonic Level Switch NQ
For liquids Contact: 1 electronic switch Connection:G 1male Material: st. st. Max. pressure:70 bar Max.temperature:125°C
|
Optical Level Sensor OPT
For liquids Contact: 1 open collector Connection: G ½ male, M14 Material: polypropylene, st. st. Max. pressure: 10 bar Max. temperature: 85°C
|
Liquid Level Switch NWS
For liquids Contact: 1 Electronic switch Connection:G 3/4, G1 male, ¾ NPT, 1 NPT male, TriClamp DIN 32676, hygenic DIN 11851 DIN-flange: DN25, DN50;ANSI-flange: 1 ,2 Material: st. st. 1.4404 Max. pressure:45 bar Max.temperature:130°C (150 °C CIP-cleaning) Viscosity: up to 5000 mm²/s
|
Vibration Switch Liquids-Plug Connection NWS-...2ES
For liquids Contact: 1 Electronic switch Connection:G 3/4, G1 male, ¾ NPT, 1 NPT male, TriClamp DIN 32676, hygenic DIN 11851 DIN-flange: DN25, DN50;ANSI-flange: 1 ,2 Material: st. st. 1.4404 Max. pressure:45 bar Max.temperature:130°C (150 °C CIP-cleaning) Viscosity: up to 5000 mm²/s Certificates: ATEX
|
Vibration Switch Liquids-Cable Connection NWS-...2F
For liquids Contact: 1 Electronic switch Connection:G 3/4, G1 male, ¾ NPT, 1 NPT male, TriClamp DIN 32676, hygenic DIN 11851 DIN-flange: DN25, DN50;ANSI-flange: 1 ,2 Material: st. st. 1.4404 Max. pressure:45 bar Max.temperature:130°C (150 °C CIP-cleaning) Viscosity: up to 5000 mm²/s Certificates: ATEX
|
Vibrating Level Switch SOLIVIB NSV
For powder, granulate Electrodes: max. 3 m Contact: 1 relay (max. 250 VAC, 1A), 25 VA Connection: G 1 ½ male Material: st. st. 1.4305 (303) Max. pressure: pressureless Max.temperature: 80 °C Power supply: 24, 110, 230 VAC, 18...36 VDC Certificates: ATEX
|
Vibrating Level Switch NVI
For powder, granulate Contact: 1 relay Connection: G 1 1/2, 1 ½ NPT male Material: st. st. 1.4571 Max. pressure: 25 bar Max.temperature: 160 °C
|
Membrane Level Monitor NMF
For bulks Contact: 1 micro switch Connection: circular flange Material: membrane: Nitril, NBR, FPM, st. st. Retaining ring: steel, stainless steel, aluminium Max. pressure: 0 bar Max. temperature: 200°C
|
Rotating Vane Level Monitor NIR-9
For bulks Contact: 1 micro switch (SPDT) Connection: G 1, G 1 1/4, G 1 1/2 male, roand flange: 110, 200 mm Material: shaft/Rotor: st. st. or aluminium Max. pressure: -0.5 bar....+0,5 bar Max .temperature: 200 °C Option: ATEX II 2/1D Ex t IIIC T85°C Db/Da
|
Capacitive Level Limit Switch for bulks NSC
Electrodes: max. 3 m, with cable 15 m Contact: 1 relay (max. 250 Vac, 1A) Connection: G 1 male, st. steel Material Electrodes: st. steel with PTFE or steel cable with PP coating Max. pressure: -0,1 bis +0,5 bar Max. temperature: -20...+80 °C Power supply: 24, 110, 230 VAC, 18..36 VDC
|
Capacitive Level Limit Switch NTS
For powder, granulate Contact: 1 open collector or relay Connection: R1 (G 1 1/2) male Material: probe PPS Max. pressure: 25 bar Max. temperature: 120°C
|
Magnetostrictive Level Meters NMT
Measuring length: 300-4000 mm Connection: G 2, 2 NPT AG Material: st. st. Max. pressure: PN 10, Max. temperature: 70 °C Accuracy: +/- 1 mm output: 4-20 mA
|
Capacitive Level Meter NMC
For liquids Measuring length: max. 4 m Connection: G 1 male, st. steel or G 2 male, PVDF Material: st. steel with PTFE or PVDF coating Max. pressure: PN 10 bar Max. temperature: 90 °C (125 °C) Power supply: 12...35 VDC (Atex 12..30 VDC) analogue output 4-20 mA
|
Continuous Level Probe LNP
Potentiometric principle For viscous, pasted, strong adhessive medias Measuring length: 200...2000 mm Connection: G 1, 1 NPT, G1 for hygenic sleeve LZE Material: st.st. 1.4404 / PEEK Max. pressure: 10 bar Max. temperature: 120°C (short time 150 °C) Accuracy: ± 1% FS Output: 4-20 mA
|
Bypass Level Indicator SZM
Measuring length: 370...3080 mm Connection: DIN-flange DN 15...DN 32 Material: st. st. 1.4571 Max. pressure: 6 bar Max. temperature: 100 °C
|
Bypass Level Indicator MBSK
Measuring length: Max. 6 meters (if longer: 2 parts) Connection: DIN-flange DN 15...DN 32 ANSI-flange 1/2 ... 1 1/4 Material: st. st. 1.4571 Max. pressure: PN 100, max. temperature:400 °C Accuracy transducer: +/- 1 mm Option: transmitter 4-20 mA, contacts
|
Mini Bypass Level Indicator NBK-M
Measuring length: Max. 3 meters Connection: DIN-flange DN 10...DN 25 ANSI-flange 1/2 ... 1 Material: st. st. 1.4571 Max. pressure: PN 40/300 lbs, max. temperature:200 °C Accuracy transducer: +/- 1 mm Option: transmitter 4-20 mA, contacts
|
Bypass Level Indicator NBK-03...NBK-33
Measuring length: Max. 6 meters (if longer: 2 parts) Connection: DIN-flange DN 15...DN 50 ANSI-flange 1/2 ... 2 Material: st. st. 1.4571 Max. pressure: PN 320, max. temperature:400 °C Accuracy transducer: +/- 1 mm Option: transmitter 4-20 mA, contacts HART, Profibus, Fieldbus
|
Bypass Level Indicator NBK with ATEX and GL
Measuring length: Max. 6 meters (if longer: 2 parts) Connection: DIN-flange DN 15...DN 32 ANSI-flange 1/2 ... 1 1/4 Material: st. st. 1.4571 Max. pressure: PN 100, max. temperature:400 °C Accuracy transducer: +/- 1 mm Option: transmitter 4-20 mA, contacts Certificates: ATEX, GL
|
Over-Head Level Indicator NBK-04
Measuring length: max. 4 m Connection: DIN-flange DN 50/65 ANSI-flange 2 / 21/2 Material: st. st. 1.4571 (316 TI) Max. pressure: PN 16, Max. temperature:120 °C Accuracy transducer: +/- 1 mm Options: transmitter 4-20 mA, contacts
|
Over-Head Level Indicator NBK-04 with ATEX
Measuring length: max. 4 m Connection: DIN-flange DN 50/65 ANSI-flange 2 / 21/2 Material: st. st. 1.4571 (316 TI) Max. pressure: PN 16, Max. temperature:120 °C Accuracy transducer: +/- 10 mm Options: transmitter 4-20 mA, contacts Certificates: ATEX
|
Bypass Level Indicator (plastic) NBK-16, -17
Measuring length: max. 4 m Connection: DIN-flange DN 20...DN 50 ANSI-flange 3/4 ...2 Material: PVC, PP, PVDF Max. pressure: 4 bar, Max. temperature: 80 °C Accuracy transducer: +/- 1 mm Options: transmitter 4-20 mA, contacts
|
Bypass Level Indicator Low Cost NBK-01
Measuring length: Max. 6 meters Connection: G ½, G 3/4, G1, G11/4 1/2, 3/4, 1, 1 ¼ NPT Material: st. st. 1.4301 Max. pressure: PN 16, Max. temperature:120 °C Accuracy transducer: +/- 1 mm Option: transmitter 4-20 mA, contacts
|
Bypass Level Indicator rope version NBK-19
or open vessels Measuring length: Max. 4,8 meters Float: PPH or st. steel Max. pressure: pressureless, max. temperature:60 °C Accuracy transducer: +/- 1 mm Option: transmitter 4-20 mA, contacts, scale
|
Limit contact for Bypass -Meter NBK-R
bistable changeover contact max. temperature: 100 °C electr. Connection: cable
|
Limit contact for Bypass -Meter NBK-RT
bistable changeover contact max. temperature: 200/400 °C electr. Connection: aluminium connection box
|
Limit contact for Bypass -Meter NBK-RA
bistable changeover contact max. temperature: 85 °C electr. Connection: cable
|
Level Indicator acc. Archimedes Principle BA
Measuring length: Max. 2x 6 meters (dependent of density) Connection: DIN-flange Material: st. st. , Hastelloy Max. pressure: 40 bar Max. Temperature: -40...+250 °C (option 300 °C) Accuracy: ± 5 mm of meas. Value Mech. pointer indication Option: transmitter 4-20 mA, contacts, ATEX, Hart, Profibus-PA
|
Ultrasonic Level Meter NUS-4
Measuring range: liquids up to 25 m Connection: G 1 ½ , G2, 11/2 NPT, 2 NPT male flange DN 80,125, 150, ANSI 3 ,5 ,6 Material Connection: Polypropylene Max. pressure: 3 bar abs., max. temperature: 90 °C Accuracy: ±0,2 % of MW ±0,05 % of ME Power supply:12-36 VDC, 2-wire Output: 4-20 mA, Relay LCD-indication and programming unit
|
Pressure Gauge with diaphragm seal for closed vessels PAD-..N
Measuring range: 0-2500 mmWc...0-150 mWc Connection: flange via neck tube DN 50 or bigger Housing Material: st. st., Hastelloy-C, Monel, Tantalum, Max. temperature: 200 °C Accuracy class: 1 / 1,6 Analogue output, HART, ATEX
|
Pressure Gauge with diaphragm seal for open vessels PAS-..N
Measuring range: 0-2500 mmWc...0-150 mWc Connection: Thread or flange DN 50 or bigger Housing Material: st. st., Hastelloy-C, Monel, Tantalum, Max. temperature: 350 °C Accuracy class: 1 / 1,6 Analogue output, HART, ATEX
|
Deep-Well Probe NTB
Measuring range: 0-1...0-200 mWc Material: st. st., cable polyurethane Max. pressure: 3x range end, max. temperature:60 °C Accuracy : ± 0,5 % FS
|
Diaphragm Level Indicator NPF
Measuring range: 0-600...0-6000 mm Wc Connection: G ½ AG Material: st. st. Max. pressure: 1,3 x max. range, max. temperature: 80 °C Accuracy: +/- 1,6 % FS Option: contacts
|
Pendulum Level Limit Switch for bulks PLS
Electrodes: max. 2 m Contact: 1 micro switch (max. 250 VAC, 3A) Connection: circular flange Ø 142 mm, aluminium Material electrodes: aluminium Pressure range: -0.1 ... +0.5 bar tmax: +80°C
|
Float Transducer-Reed Chain MM
Measuring length: max. 6 m Connection: R ⅜ ... R 2, DIN-flange DN40 ... DN125, ASME 1½" - 4" Material: stainless steel, PVC, PPH, PTFE pmax: 30 bar tmax: 130°C Accuracy: 0.5 % for L = 2 m Output: resistor, 4 - 20 mA, LED/LCD-display, contacts, HART®, Profibus® PA, Fliedbus®
|
Mini-Bypass Level Indicator NZJ
Installation length: 100 ... 540 mm pmax: 16 bar tmax: 100°C Viscosity: max. 50mm²/s Connection: G1/4, 1/4" NPT (male) union nut Material: stainless steel (1.4301/1.4404) / aluminim Options/Feature: lokale indicator without auxiliary power, limit contacts
|
Guided Radar Level Transmitter NGR
Measuring range: up to 2 m Connection: G ¾ , ¾" NPT male thread Material connection: stainless steel, PTFE Pressure range: -1 ... +10 bar Temperature range: -20 ... +100°C Accuracy: ±5 mm Power supply: 12 - 30 VDC, 2-wire Output: 4 - 20 mA, 0 - 10 V, Switching output 1x PNP, 3x PNP / NPN
|
Guided Radar Level Transmitter NGM
Measuring range: liquids up to 20 m Connection: G ¾ , ¾" NPT male thread, flange DN40 ... DN100, ANSI 1½"... 4" Material connection: stainless steel, PTFE Pressure range: -1 ... +40 bar Temperature range: -50 ... +250°C Accuracy: ±3 mm or 0.03 % of reading Power supply: 12 - 30 VDC, 4-wire Output: 4 - 20 mA, switching output PNP
|
Non-Contact Radar Level Transmitter - NRM
Measuring range: liquids up to 23 m Connection: G- ,NPT- thread male Flange 3"... 6" (DN, ANSI, JIS) Dairy connection, TriClamp Material connection: stainless steel, PP, PTFE pmax: 25 bar tmax: +180°C Accuracy: ±3 mm Power supply: 20 - 36 VDC (Ex= 20 - 30 VDC) , 2-wire Output: 4 - 20 mA HART Approval: Ex ia (ATEX & IECEX)
|
Ultrasonic Level Meter NUS-7
Measuring range: liquids 0.25 ... 6 m Connection: G 2, 2" NPT male thread Material connection: polypropylene or PVDF Pressure range: 0.25 ... 3 bar abs. tmax: 80°C Accuracy: ±0.2 % of reading ±0.05 % of full scale Power supply: 12 - 36 VDC, 2-wire Electrical connection: PVC-cable Output: 4 - 20 mA, relay, HART®
|
Differential Pressure Transmitter PAD
Measuring range: 0.75 - 15 mbar ... 4.137 - 413.7 bar Connection: ¼" NPT, ½" NPT Housing material: stainless steel, Hastelloy-C®, Monel, tantalum tmax: 120°C Accuracy: ±0.075 % of span Analogue output: 4 - 20 mA, HART®, ATEX Option: frequency output / totalizer for flow measurement
|
Pressure Transmitter PAS
Measuring range: -1 ... +600 bar Power supply: 11.9 - 45 VDC Connection: ¼" NPT female thread, ½" NPT female thread Accuracy: ±0.075 % of calibrated span
|
|
|
|