Humidity/temperature Measuring Instrument AFH-G
Operating temperature: -30...+80 °C umidity: 30..100 % RH Probe: polymer fibre inside st. st. housing, 220 mm Max. pressure: pressureless Max. temperature: -20...60 °C (housing), -40..+80 °C (sensor) Accuracy of temperature: ±0, 5 °C humidity: ± 2,5 % RH (<40% RH: ± 3,5 % RH) Output: temperature: Pt100 or 4-20 mA humidity: 100-138,5 Ohm or 4-20 mA
|
|
Humidity/temperature Measuring Instrument (capacitive) AFK-G
Operating range: temperature: -60...+200 °C humidity: 0... 100 % RH Max. pressure: 25 bar Max. temperature: +200 °C Accuracy of temperature: ±0,1 °C humidity: ± 2 %RH Output: 2 x 4-20 mA
|
|
Humidity/temperature Measuring Instrument (capacitive) AFK-G2
Operating range: temperature: -60...+200 °C humidity: 0... 100 % RH Max. pressure: 25 bar Max. temperature: +200 °C Accuracy of temperature: ±0,1 °C humidity: ± 2 %RH Output: 2 x 4-20 mA
|
|
Humidity Measuring Instrument with Indicator (capacitive) AFA-G
Operating range: 0 - 100 % RH Max. pressure: pressureless Max. temperature: 0...60 °C Accuracy : ± 2 % RH (5...95 % RH) output: 4-20 mA Plug-on display: 3,5-digit LED Option: limit switch
|
|
Humidity/Temperature Transmitter AFK-E
For Industrial applications Operating range temperature: -40...+180 °C humidity: 0... 100 % RH Max. pressure: 15 bar Max. temperature: -40...60 °C (housing), -40...+180 °C (sensor) Accuracy of temperature: ±0, 2 °C humidity: ± 2 % RH (0..90% RH) Output: 0-5 V, 0-10V, 4-20 mA Dew-point temperature, Freezing point temperature, abs. humidity, specific enthalpy, Water-vapuor partial pressure, mixing ratio
|
|
Room Hygrostat AFS-G2
Operating range: 35 - 100 % RH Max. pressure: pressureless Max. temperature: 0...60 °C Accuracy: ± 3 % RH Contact: 1 micro switch, adjustable
|
|
Humidity Annex Switch AFS-G3
Operating range: 50 - 100 % RH Max. pressure: pressureless Max. temperature: 0...60 °C Accuracy: ± 3 %RH Contact: 1 micro switch, adjustable from inside
|
|
Hygrostat AFS-G1
Operating range: 35 - 100 % RH Probe: polymere fibres inside st. st. housing, 220 mm Max. pressure: pressureless Max. temperature: -30...60 °C Accuracy: ± 3,5 % RH (<50%RH: ± 4 % RH) Contact: 1 micro switch
|
|
Hand-Held Humidity Precision Measuring Unit HND-F
For weight moisture or relative humidity Measuring range: 0 -100 % rel. humidity Accuracy: ± 0,1 / 0,2 % of rel.humidity Supply: 9 V battery Holding Function, min/max. -memory, alarm, data logger, output 0-1 V, RS 232 Option: temperature-, flow measuring
|